Products — Power Supply & Distribution

DT-0.4-1500 Throttle Transformer for Electric Railways

DT-0.4-1500 Throttle Transformer for Electric Railways

$900-3,000
TERMOTRON-ZAVOD LLC 🇷🇺
Lead-Acid Starter Battery 6ST-55VL AUTO FAN

Lead-Acid Starter Battery 6ST-55VL AUTO FAN

$18-54
AKOM OJSC 🇷🇺
Dry Single-Phase Transformer PT-25M-2

Dry Single-Phase Transformer PT-25M-2

$15-60
ELTEZA OJSC 🇷🇺
Lead Acid Starter Battery 6ST-58 N, L, LY, VL

Lead Acid Starter Battery 6ST-58 N, L, LY, VL

$21-60
AKTECH ENERGY TRADE LLC 🇷🇺
Throttle Transformer DTE-0.4-1500CN (n=3)

Throttle Transformer DTE-0.4-1500CN (n=3)

$90-360
ELTEZA OJSC 🇷🇺
AC Choke Transformers 2DT-1MG1-300

AC Choke Transformers 2DT-1MG1-300

$90-360
ELTEZA OJSC 🇷🇺
Single-Phase Antiresonant Voltage Transformer NAMI-330 U1

Single-Phase Antiresonant Voltage Transformer NAMI-330 U1

$9,000-30,000
RETZ ENERGY OJSC 🇷🇺
Capacitive Voltage Transformer NDKM-330 UHL1

Capacitive Voltage Transformer NDKM-330 UHL1

$9,000-30,000
RETZ ENERGY OJSC 🇷🇺
Grounding Voltage Transformer ZNOLP-EC M8

Grounding Voltage Transformer ZNOLP-EC M8

$900-4,200
ELECTROSHIT-K° LLC 🇷🇺
Anti-Resonance Single-Phase Voltage Transformer NAMI Series

Anti-Resonance Single-Phase Voltage Transformer NAMI Series

$9,000-36,000
RETZ ENERGY OJSC 🇷🇺
Anti-resonant Three-phase Voltage Transformer NAMI-35 UHL1

Anti-resonant Three-phase Voltage Transformer NAMI-35 UHL1

$4,200-15,000
RETZ ENERGY OJSC 🇷🇺
Grounded Voltage Transformer ZNOL-EK MN40

Grounded Voltage Transformer ZNOL-EK MN40

$900-6,000
ELECTROSHIT-K° LLC 🇷🇺
Grounding Voltage Transformer ZNOL-EC M11

Grounding Voltage Transformer ZNOL-EC M11

$900-3,600
ELECTROSHIT-K° LLC 🇷🇺
Grounded Voltage Transformer ZNOL-EK MN41

Grounded Voltage Transformer ZNOL-EK MN41

$450-1,800
ELECTROSHIT-K° LLC 🇷🇺
Anti-Resonance Single-Phase Voltage Transformer NAMi-220 UHL1

Anti-Resonance Single-Phase Voltage Transformer NAMi-220 UHL1

$15,000-48,000
RETZ ENERGY OJSC 🇷🇺
Inductive Gas-Filled Voltage Transformer ZNOG-110

Inductive Gas-Filled Voltage Transformer ZNOG-110

$9,000-30,000
ZETO CJSC 🇷🇺
Grounded Voltage Transformer ZNOL(P)-NTZ-6(10;20;35)

Grounded Voltage Transformer ZNOL(P)-NTZ-6(10;20;35)

$900-4,200
NTZ VOLKHOV LLC 🇷🇺
Grounding Voltage Transformer ZNOLP-EC M6

Grounding Voltage Transformer ZNOLP-EC M6

$90-360
ELECTROSHIT-K° LLC 🇷🇺
Grounding Voltage Transformer NOL-EC M1

Grounding Voltage Transformer NOL-EC M1

$90-360
ELECTROSHIT-K° LLC 🇷🇺
Capacitive Voltage Transformer NDKM-500 UHL1

Capacitive Voltage Transformer NDKM-500 UHL1

$42,000-150,000
RETZ ENERGY OJSC 🇷🇺
Three-Phase Voltage Transformers NALI-SESH

Three-Phase Voltage Transformers NALI-SESH

$900-4,200
ELECTROSHIT Group OJSC - SAMARA TM 🇷🇺
Non-Earthed Voltage Transformers NOL-3 kV

Non-Earthed Voltage Transformers NOL-3 kV

$900-3,600
SZTT OJSC 🇷🇺
Grounding Voltage Transformer ZNOLP-EK M12

Grounding Voltage Transformer ZNOLP-EK M12

$150-900
ELECTROSHIT-K° LLC 🇷🇺
Grounding Voltage Transformer NOLP-EC M2

Grounding Voltage Transformer NOLP-EC M2

$150-840
ELECTROSHIT-K° LLC 🇷🇺
Grounding Voltage Transformers ZNOL.01PMI-35

Grounding Voltage Transformers ZNOL.01PMI-35

$150-600
SZTT OJSC 🇷🇺
Grounding Voltage Transformer ZNOL-EC M10

Grounding Voltage Transformer ZNOL-EC M10

$90-840
ELECTROSHIT-K° LLC 🇷🇺
Grounded Voltage Transformer NOLP-EC M1

Grounded Voltage Transformer NOLP-EC M1

$90-540
ELECTROSHIT-K° LLC 🇷🇺
Grounding Voltage Transformer ZNOLP-EK M7

Grounding Voltage Transformer ZNOLP-EK M7

$1,500-5,400
ELECTROSHIT-K° LLC 🇷🇺
Grounding Voltage Transformer ZNOL-EC M5

Grounding Voltage Transformer ZNOL-EC M5

$300-1,800
ELECTROSHIT-K° LLC 🇷🇺
Voltage Transformer NOP-NTZ-1

Voltage Transformer NOP-NTZ-1

$15-60
NTZ VOLKHOV LLC 🇷🇺
Grounding Voltage Transformer ZNOL-EK M9

Grounding Voltage Transformer ZNOL-EK M9

$90-540
ELECTROSHIT-K° LLC 🇷🇺

Transformers, UPS and Power Supplies for Grid and Facility Projects

From a wall-mounted power module to a packaged substation, this 3,015-listing category from 532 suppliers covers the full power conversion chain. The depth is in the mid-range: 474 power supplies and modules, 306 starter batteries, 303 inverters, rectifiers and chargers, 269 stationary and lithium-ion batteries, 249 power transformers, 230 uninterruptible power supplies, 171 instrument current transformers and 85 voltage transformers, 119 special and choke transformers, 109 switchgear positions, 74 packaged substations, plus measurement transducers and voltage stabilizers.

Transformer building is a long-standing Russian export strength — machines for utilities across Asia, Africa and Latin America have come from these plants for decades, and service infrastructure for them already exists in many importing countries. The battery and UPS segment grew more recently on telecom and data-centre demand. Across the category, equipment is engineered for wide temperature ranges and tolerant of grid disturbance, with routine factory testing documented per unit.

  • Utility equipment: distribution transformers and packaged substations configured to your network voltages and vector groups.
  • Factory tests: routine test protocols per transformer and UPS; witnessed acceptance available for utility orders.
  • Battery logistics: lithium systems ship under dangerous-goods rules; suppliers prepare UN-compliant packaging and documents.
  • Order scale: single units for facilities; framework contracts for utility tender volumes.
  • Delivery: FOB Novorossiysk or St. Petersburg; rail and truck across the EAEU and Central Asia.

State your network parameters and load profile in a sourcing request and manufacturers will configure and quote the equipment.

FAQ

Can distribution transformers be built for my national grid parameters?
Yes. Plants wind to your primary and secondary voltages, vector group, tap range and frequency, and apply the cooling and climatic execution your site needs. Provide the network one-line data and ambient conditions; the factory returns a technical proposal with losses, impedance and dimensions for approval before production, which typically takes 8–16 weeks.
What testing documentation accompanies a transformer?
Every unit passes routine tests — winding resistance, ratio, insulation, applied and induced voltage, losses — documented in a protocol shipped with the transformer. Type test reports for the design are available for tender files. Utility buyers can witness factory acceptance in person or by video link, which suppliers arrange routinely.
How are lithium batteries and UPS systems shipped internationally?
Lithium-ion batteries travel as Class 9 dangerous goods: UN-certified packaging, state-of-charge limits and dangerous goods declarations, which suppliers prepare. Sea freight is the standard mode; air carries tighter restrictions. Lead-acid and VRLA batteries ship with simpler paperwork. Factor 1–2 extra weeks for DG documentation on first orders.
Do UPS suppliers help size the system for my facility?
Yes — send the load list, required autonomy and site temperature, and the supplier proposes UPS rating, battery configuration and ventilation requirements. For data-centre and telecom projects, redundancy schemes and monitoring integration are specified at this stage. Sizing calculations are part of the quotation, not a paid extra.
Is commissioning support available for packaged substations?
Packaged substations ship factory-assembled and tested, with installation and earthing drawings. Supervised commissioning by a factory engineer is a contract option many utility buyers take for the first units, then handle subsequent ones with their own crews. Remote support and spare-parts kits are agreed in the supply contract.
What payment structure is usual for large electrical equipment?
Typical terms are 30–50 percent advance with the balance before shipment by bank transfer; letters of credit are workable with larger plants if banking channels are agreed early. For framework utility contracts, milestone payments tied to factory acceptance tests are common practice.