Input signal frequency range
0.009...14500
Limits of permissible absolute error of setting the power level of the output signal (in the frequency range from 0,1 Hz to 1000
1分贝毫
Upper limit of the frequency range of the output signal
13000
Lower limit of the output frequency range
0.1
Power spectral density of phase noise (at 1 GHz frequency, at 1 kHz detuning), not exceeding
-110 分贝/赫兹
Maximum output signal power level (in the frequency range from 0,1 Hz to 10000 MHz), not less than
15 dBm
Minimum frequency bandwidth of the measuring filter
1.5
Average displayed intrinsic noise level, not more
-155 dBm/赫兹,在6000到10000兆赫的频率范围内
Power spectral density of phase noise (at 100 MHz, at 1 kHz detuning), not more
-120 分贝/赫兹
Limits of permissible error of input signal level measurement (in the frequency range from 10 kHz to 10000 MHz), not more than
1 dBm
Dynamic range of measurement of signal levels, not less than
100
Output signal frequency range
20...20000
Maximum power level of the output signal (in the frequency range from 100 to 20000 Hz, with additional amplifier switched on)
25 dBm
Calibration coefficient determination error, not more than
2
Calibration coefficient, max.
30 dB (1/m) 在 1 GHz 频率下
Lower limit of the operating frequency range, max.
0.009
Lower limit of the operating frequency range, max.
1 GHz
Gain factor, not less (calibration factor, not more)
在10 GHz时至少为8 dB(42 dB)
Upper limit of the operating frequency range, not less than
10 赫兹
Upper limit of the operating frequency range, not less than
10000
Error of gain determination or calibration, not more than
2
Calibration determination error, not more than
2
Lower limit of the operating frequency range, max.
0.009
Upper limit of the operating frequency range, not less than
30
Lower limit of the operating frequency range, max.
0.009
Upper limit of the operating frequency range, not less than
10000
Error of gain determination or calibration, not more than
2
Gain factor, not less (calibration factor, not more) in the range from 1 to 10 GHz
在10 GHz时至少为8 dB(42 dB)
Calibration factor in the frequency range from 100 MHz to 1 GHz, not more
30 dB (1/m) 在 1 GHz 频率下
Operating voltage (DC component), max.
100 V
Upper limit of the operating frequency range, not less than
400
Lower limit of the operating frequency range, max.
0.009
Upper limit of the operating frequency range, not less than
400
Lower limit of the operating frequency range, max.
0.009
Level of generated current, not less than
5 dB(毫安)
Upper limit of the operating frequency range, not less than
400
Lower limit of the operating frequency range, max.
0.009
Output impedance
SBVVBG ohm
Calibration coefficient determination error, not more than
3
Calibration coefficient (at 50 ohm load), max.
0 dB(1/Ω) 在 200 到 400 MHz 范围内
Instability of integral sound pressure level during continuous operation, not more than
2
Magnitudes of the scattering fields (field strength), at maximum input power, at a distance of 1 m along the transmitter axis, n
磁场 20 µA/m
Уровень октавного звукового давления, создаваемого на расстоянии 1 м, не менее
105 dB for fifth, sixth and seventh octaves
Frequency response unevenness in octave bands, no more than
6
Upper limit of the operating frequency range, not less than
11200
Lower limit of the operating frequency range, max.
100
Unevenness of AFC in sound pressure, not more
2
Sensitivity by free field, not less than
至少10毫伏/帕
Upper limit of the operating frequency range, not less than
11200
Lower limit of the operating frequency range, max.
100
Lower limit of the operating frequency range, max.
100
Upper limit of the operating frequency range, not less than
11200
Error of sound pressure level measurement, not more
2分贝
Sound pressure measurement range (RH 2x10-5 Pa)
20...120
Lower limit of the operating frequency range, max.
0.009
Upper limit of the operating frequency range, not less than
400
Wire brands
TSV, NYM, KSPeV, TPP, UTP5e
Length of each wire, no less than
5 m