产品 — 电缆与布线

Medium Voltage Power Cable AПвПу2гж

Medium Voltage Power Cable AПвПу2гж

¥64.80-259.20
EM-KABEL LLC 🇷🇺
Flame-Retardant Power Cables with Aluminum Conductors

Flame-Retardant Power Cables with Aluminum Conductors

¥6.48-25.92
MOSKABEL LLC 🇷🇺
High Voltage Power Cable with Copper Conductors, 10-35 kV, PvBPg

High Voltage Power Cable with Copper Conductors, 10-35 kV, PvBPg

¥64.80-259.20
KAMSKY CABLE LLC 🇷🇺
Low Fire Hazard Power Cables 0.66-1 kV, AПвКШвнг(А)-LS

Low Fire Hazard Power Cables 0.66-1 kV, AПвКШвнг(А)-LS

¥6.48-43.20
EXPERT-KABEL LLC 🇷🇺
Low Fire Hazard Power Cables VBSHvnG(A)-LS for Voltage Up to 1 kV

Low Fire Hazard Power Cables VBSHvnG(A)-LS for Voltage Up to 1 kV

¥6.48-43.20
Ludinovokabel OJSC 🇷🇺
Copper Power Cable K9SPv with Cross-Linked Polyethylene Insulation

Copper Power Cable K9SPv with Cross-Linked Polyethylene Insulation

¥64.80-259.20
UGLICHKABEL LLC 🇷🇺
Power Cable PVC LS with Copper Conductors - PВГнг(А)-LS

Power Cable PVC LS with Copper Conductors - PВГнг(А)-LS

¥4.32-43.20
SKT GROUP LLC 🇷🇺
Low-Flammability Control Cables 0.66-10 kV AKVBSHvng(A)

Low-Flammability Control Cables 0.66-10 kV AKVBSHvng(A)

¥6.48-43.20
EXPERT-KABEL LLC 🇷🇺
Power Cable PvPg 1x185/95-64/110 kV

Power Cable PvPg 1x185/95-64/110 kV

¥64.80-216
EKZ OJSC 🇷🇺
Power Cable with Aluminum Conductors, XLPE Insulation, APEB

Power Cable with Aluminum Conductors, XLPE Insulation, APEB

¥64.80-259.20
KAMSKY CABLE LLC 🇷🇺
Universal Power Cable with Aluminum Conductors, XLPE Insulation, 6-35kV

Universal Power Cable with Aluminum Conductors, XLPE Insulation, 6-35kV

¥10.80-129.60
KAMSKY CABLE LLC 🇷🇺
Power Cable with Aluminum Conductors, XLPE Insulation, APvBP2g Model

Power Cable with Aluminum Conductors, XLPE Insulation, APvBP2g Model

¥64.80-259.20
KAMSKY CABLE LLC 🇷🇺
High Voltage Power Cable with Copper Conductors, PvkPNG(A)-HF

High Voltage Power Cable with Copper Conductors, PvkPNG(A)-HF

¥64.80-259.20
KAMSKY CABLE LLC 🇷🇺
Power Cable PvPu2gzh 1x300mk/120-10kV

Power Cable PvPu2gzh 1x300mk/120-10kV

¥64.80-216
EKZ OJSC 🇷🇺
Halogen-Free Copper Conductor Cable 1x630/150-64/110 kV

Halogen-Free Copper Conductor Cable 1x630/150-64/110 kV

¥64.80-216
EKZ OJSC 🇷🇺
Copper Core Insulated Wires for 110-220 kV Cable Connections

Copper Core Insulated Wires for 110-220 kV Cable Connections

¥64.80-259.20
KAMSKY CABLE LLC 🇷🇺
Power Cable APvP 3x150mm²/25-10kV

Power Cable APvP 3x150mm²/25-10kV

¥6.48-25.92
EKZ OJSC 🇷🇺
Power Cable with Aluminum Conductors, XLPE Insulated, APvV2gzhng

Power Cable with Aluminum Conductors, XLPE Insulated, APvV2gzhng

¥64.80-259.20
KAMSKY CABLE LLC 🇷🇺

常见问题

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.