产品 — 电缆与布线

Heat-Shrinkable Connector Joint 10СТп (o.p.)-7M

Heat-Shrinkable Connector Joint 10СТп (o.p.)-7M

¥64.80-259.20
THERMOFIT LLC 🇷🇺
MyFTA KVNTP-1-3x(25-50) End Cable Joint for Insulated Cables

MyFTA KVNTP-1-3x(25-50) End Cable Joint for Insulated Cables

¥64.80-216
RIKA GROUP LLC 🇷🇺
End Cap Heat Shrinkable Joint 10KVTP0N-2

End Cap Heat Shrinkable Joint 10KVTP0N-2

¥64.80-216
THERMOFIT LLC 🇷🇺
Heat-Shrink End Joint for 1 kV Cables - 1КВТп-5

Heat-Shrink End Joint for 1 kV Cables - 1КВТп-5

¥21.60-129.60
THERMOFIT LLC 🇷🇺
MyFTA PSTp (ngLS)-1-3x(150-240) Cable Joint Connector

MyFTA PSTp (ngLS)-1-3x(150-240) Cable Joint Connector

¥12.96-69.12
RIKA GROUP LLC 🇷🇺
MyFTA STPU-10X3 Cable Joint Connector (150/240)

MyFTA STPU-10X3 Cable Joint Connector (150/240)

¥64.80-259.20
RIKA GROUP LLC 🇷🇺
MyFTA PSTpb-10-3x(70-120)-bg Cable Jointing Sleeve

MyFTA PSTpb-10-3x(70-120)-bg Cable Jointing Sleeve

¥108-432
RIKA GROUP LLC 🇷🇺
End Cable Joint The MyFTA KNTp-10 3Х(25-50)

End Cable Joint The MyFTA KNTp-10 3Х(25-50)

¥108-432
RIKA GROUP LLC 🇷🇺
End Cable Joint The MyFTA PKVNTp-1-5x(25-50)

End Cable Joint The MyFTA PKVNTp-1-5x(25-50)

¥21.60-129.60
RIKA GROUP LLC 🇷🇺
Heat Shrinkable Jointing Sleeve 1PSTp0-3

Heat Shrinkable Jointing Sleeve 1PSTp0-3

¥6.48-25.92
THERMOFIT LLC 🇷🇺
MyFTA PKVTp-20-1x(300-400) Indoor Cable Joint

MyFTA PKVTp-20-1x(300-400) Indoor Cable Joint

¥64.80-259.20
RIKA GROUP LLC 🇷🇺
Outdoor Cable Joint MyFTA PKNTp-20-3x(25-50) for XLPE Cables

Outdoor Cable Joint MyFTA PKNTp-20-3x(25-50) for XLPE Cables

¥64.80-259.20
RIKA GROUP LLC 🇷🇺
Plastic Insulated Cable Connector 5ПСТб-1-35/50(Б)

Plastic Insulated Cable Connector 5ПСТб-1-35/50(Б)

¥6.48-25.92
GARDIFLOW LLC 🇷🇺
Heat Shrink End Cap for Three-Core Cable 10PKNTpL-7

Heat Shrink End Cap for Three-Core Cable 10PKNTpL-7

¥64.80-216
THERMOFIT LLC 🇷🇺
MyFTA KVTpN(ngLS)-35-3x(150-240) End Cable Joint

MyFTA KVTpN(ngLS)-35-3x(150-240) End Cable Joint

¥648-2,160
RIKA GROUP LLC 🇷🇺
3PKNTp-35 Outdoor Cable Termination for Power Cables

3PKNTp-35 Outdoor Cable Termination for Power Cables

¥64.80-259.20
MZEI OJSC 🇷🇺
MyFTA PSTpb-1-5x(25-50) Cable Jointing Sleeve

MyFTA PSTpb-1-5x(25-50) Cable Jointing Sleeve

¥21.60-129.60
RIKA GROUP LLC 🇷🇺
Heat Shrinkable Connective Sleeve 1PSTpB (4*10)

Heat Shrinkable Connective Sleeve 1PSTpB (4*10)

¥21.60-129.60
THERMOFIT LLC 🇷🇺
Internal Cable Joint MyFTA PKVTPN(ngLS)-20-1x(150-240)

Internal Cable Joint MyFTA PKVTPN(ngLS)-20-1x(150-240)

¥108-432
RIKA GROUP LLC 🇷🇺
MyFTA PSTpb(нгLS)-20-1x(150-240) Cable Joint Connector

MyFTA PSTpb(нгLS)-20-1x(150-240) Cable Joint Connector

¥64.80-259.20
RIKA GROUP LLC 🇷🇺
Heat Shrinkable Branch Joint 1P3OTpB-1/X

Heat Shrinkable Branch Joint 1P3OTpB-1/X

¥34.56-129.60
THERMOFIT LLC 🇷🇺
Heat Shrink End Cap for Plastic Insulated Cables 1P2KNTpN-1

Heat Shrink End Cap for Plastic Insulated Cables 1P2KNTpN-1

¥10.80-43.20
THERMOFIT LLC 🇷🇺
End Termination Heat Shrinkable 35kV for Paper Insulated Cable

End Termination Heat Shrinkable 35kV for Paper Insulated Cable

¥345.60-1,296
THERMOFIT LLC 🇷🇺

常见问题

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.