产品 — 电缆与布线

Self-Supporting Conductor SIP-1 3x70+1x70-06/1 kV

Self-Supporting Conductor SIP-1 3x70+1x70-06/1 kV

¥10.80-34.56
EKZ OJSC 🇷🇺
Insulated Self-Supporting Wires, 16-240 mm², Aluminum Alloy

Insulated Self-Supporting Wires, 16-240 mm², Aluminum Alloy

¥6.48-43.20
Irkutskkabel OJSC 🇷🇺
Self-Supporting Insulated Wires SIPg-4

Self-Supporting Insulated Wires SIPg-4

¥4.32-25.92
EXPERT-KABEL LLC 🇷🇺
SIP-3 Aerial Bundled Conductor with Steel-Aluminum Core

SIP-3 Aerial Bundled Conductor with Steel-Aluminum Core

¥6.48-25.92
BALTKABEL LLC 🇷🇺
Self-Supporting Insulated Wires SIPn-4 for Power Transmission

Self-Supporting Insulated Wires SIPn-4 for Power Transmission

¥6.48-25.92
Samara Cable Company OJSC 🇷🇺
SIP-2 Wire 3x25+1x35-0.6/1 (GOST) TU 16-705.500-2006

SIP-2 Wire 3x25+1x35-0.6/1 (GOST) TU 16-705.500-2006

¥6.48-21.60
KAMSKY CABLE LLC 🇷🇺
Self-Supporting Insulated Wire SIP-3 1x95-20

Self-Supporting Insulated Wire SIP-3 1x95-20

¥6.48-21.60
PENN LLC 🇷🇺
Self-Supporting Insulated Wire SIP-2 3x95+1x50-0.6/1

Self-Supporting Insulated Wire SIP-2 3x95+1x50-0.6/1

¥6.48-21.60
PENN LLC 🇷🇺
SIP-1ts 3x50+1x50+1x25 Lighting Cable 0.6/1 kV

SIP-1ts 3x50+1x50+1x25 Lighting Cable 0.6/1 kV

¥6.48-21.60
Irkutskkabel OJSC 🇷🇺
Cable Coupling KM-U-UKP SO for Microprocessor Devices

Cable Coupling KM-U-UKP SO for Microprocessor Devices

¥216-1,296
UZhDA LLC 🇷🇺
Fire-Retardant Heat Shrink Tubing TТЭнг-С

Fire-Retardant Heat Shrink Tubing TТЭнг-С

¥2.16-17.28
MEMOTHERM-MM OJSC 🇷🇺
4PKVT-1 Heat Shrink Cable Termination Kit (10-240mm²) MKS

4PKVT-1 Heat Shrink Cable Termination Kit (10-240mm²) MKS

¥10.80-43.20
MZEI OJSC 🇷🇺
Heat Shrink Tubing TUT - Insulation for Electrical Connectors

Heat Shrink Tubing TUT - Insulation for Electrical Connectors

¥2.16-17.28
MEMOTHERM-MM OJSC 🇷🇺
Heat Shrink Tubing TUTk (Adhesive) for Electrical Insulation

Heat Shrink Tubing TUTk (Adhesive) for Electrical Insulation

¥6.48-43.20
MEMOTHERM-MM OJSC 🇷🇺
Heat Shrinkable Connecting Sleeve MyFTA STp-1-3x(70-120)

Heat Shrinkable Connecting Sleeve MyFTA STp-1-3x(70-120)

¥64.80-259.20
RIKA GROUP LLC 🇷🇺
Heat Shrinkable Joint for 35kV Cables - 35СТп-8

Heat Shrinkable Joint for 35kV Cables - 35СТп-8

¥64.80-259.20
THERMOFIT LLC 🇷🇺
Polyethylene Cable Restoration Coupling MRP

Polyethylene Cable Restoration Coupling MRP

¥6.48-25.92
SSD OJSC 🇷🇺
1PKVT-10 Cable Termination Kits for 10kV Power Cables

1PKVT-10 Cable Termination Kits for 10kV Power Cables

¥64.80-259.20
MZEI OJSC 🇷🇺
SttO-500 Connection Coupling for Armored Cables

SttO-500 Connection Coupling for Armored Cables

¥64.80-259.20
RIKA GROUP LLC 🇷🇺
High-Performance Patch Cord Cable ADIV.465249.002TU with Heat Shrink Tube

High-Performance Patch Cord Cable ADIV.465249.002TU with Heat Shrink Tube

¥2.16-17.28
Research Institute of Information Technologies OJSC 🇷🇺
1PKNT-10 Cable Terminations for 10kV Power Cables

1PKNT-10 Cable Terminations for 10kV Power Cables

¥64.80-259.20
MZEI OJSC 🇷🇺
Cable Connectors 3STpl-1 and 4STpl-1 for Power Cables

Cable Connectors 3STpl-1 and 4STpl-1 for Power Cables

¥21.60-129.60
MZEI OJSC 🇷🇺

常见问题

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.