Товарлар — Кабелдер жана зымдар

Кабелдер кичинекей КМПВЭ

Кабелдер кичинекей КМПВЭ

сом 52.20-522
Podolsk Cable OJSC 🇷🇺
Кабель ВВГнг(А)-LS-ХЛ

Кабель ВВГнг(А)-LS-ХЛ

сом 52.20-313.20
KABELNY ZAVOD KABEX LLC 🇷🇺
Кабель ВВГЭнг(А)

Кабель ВВГЭнг(А)

сом 26.10-156.60
EKZ OJSC 🇷🇺
Flame-Retardant Power Cables for 0.66 and 1 kV Applications

Flame-Retardant Power Cables for 0.66 and 1 kV Applications

сом 52.20-522
Irkutskkabel OJSC 🇷🇺
20-010710 Кабельдик кыстаргыч

20-010710 Кабельдик кыстаргыч

сом 13.05-78.30
ROSISOLIT LLC 🇷🇺
Күч берүүчү кабель ПВС-ВП 3*0,75 C13

Күч берүүчү кабель ПВС-ВП 3*0,75 C13

сом 52.20-261
ELECTRIC MANUFACTURE LLC 🇷🇺
Т-отвод кабельроста DKZ 000 T

Т-отвод кабельроста DKZ 000 T

сом 261-3,132
SZ EMI OJSC 🇷🇺
Kabel silovoy APPG-Png(A)-HF

Kabel silovoy APPG-Png(A)-HF

сом 78.30-261
Alyur Cable Plant LLC 🇷🇺
Cable Entry Type VK53-1Ex e IIC Gb for Flexible Cables

Cable Entry Type VK53-1Ex e IIC Gb for Flexible Cables

сом 783-3,132
VELAN OJSC 🇷🇺
Kabel antivibratsionnyy 03L1B1

Kabel antivibratsionnyy 03L1B1

сом 261-1,566
GTLAB LLC 🇷🇺
SeKav ПвКПнг(А)-HF күчөтүү кабели

SeKav ПвКПнг(А)-HF күчөтүү кабели

сом 78.30-313.20
KAVKAZKABEL LLC 🇷🇺
Кабель ВБШв

Кабель ВБШв

сом 26.10-313.20
EKZ OJSC 🇷🇺
Kabel OKTs-ng(A)-HF

Kabel OKTs-ng(A)-HF

сом 783-3,132
INKAB LLC 🇷🇺
Kabel silovoy PvVG-HL

Kabel silovoy PvVG-HL

сом 52.20-313.20
KAVKAZKABEL LLC 🇷🇺
KPV-O башкаруу кабелдери

KPV-O башкаруу кабелдери

сом 78.30-313.20
Podolsk Cable OJSC 🇷🇺
DPOm-P Cable for Suspension Between Structures

DPOm-P Cable for Suspension Between Structures

сом 783-3,132
INKAB LLC 🇷🇺

FAQ

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.