محصولات — کابل‌ها و سیم‌کشی

کابل‌های قدرت با علامت تجاری روسکی سوئیت® AВВГнг(А)-LSLTx

کابل‌های قدرت با علامت تجاری روسکی سوئیت® AВВГнг(А)-LSLTx

﷼ 25,200-151,200
ENERGO-KABEL OJSC 🇷🇺
کابل قدرت AВВГЭнг(А)

کابل قدرت AВВГЭнг(А)

﷼ 37,800-151,200
KAVKAZKABEL LLC 🇷🇺
EPRon® Power Cable with Aluminum Conductors and Ethylene-Propylene Insulation

EPRon® Power Cable with Aluminum Conductors and Ethylene-Propylene Insulation

﷼ 378,000-1,764,000
KAMSKY CABLE LLC 🇷🇺
کابل قدرت با هسته آلومینیومی AABVG-6 3x150(عایق)

کابل قدرت با هسته آلومینیومی AABVG-6 3x150(عایق)

﷼ 63,000-176,400
KAMSKY CABLE LLC 🇷🇺
Power Cables with Aluminum Conductors and Plastic Insulation, 3 kV, AVVGng(A)

Power Cables with Aluminum Conductors and Plastic Insulation, 3 kV, AVVGng(A)

﷼ 25,200-252,000
MOSKABEL LLC 🇷🇺
High Voltage Power Cable KA9RV 6-35kV Aluminum with EPR Insulation

High Voltage Power Cable KA9RV 6-35kV Aluminum with EPR Insulation

﷼ 378,000-1,260,000
UGLICHKABEL LLC 🇷🇺
High Voltage Power Cable AПвПу2г 1*240(гж)/95-87/150

High Voltage Power Cable AПвПу2г 1*240(гж)/95-87/150

﷼ 37,800-126,000
Irkutskkabel OJSC 🇷🇺
6-10kV Power Cable with Aluminum Conductors and Paper Insulation

6-10kV Power Cable with Aluminum Conductors and Paper Insulation

﷼ 75,600-403,200
KAMSKY CABLE LLC 🇷🇺
Power Cable APvKV - Aluminum Conductors with XLPE Insulation

Power Cable APvKV - Aluminum Conductors with XLPE Insulation

﷼ 63,000-756,000
EM-KABEL LLC 🇷🇺
Low Smoke Zero Halogen Power Cables with Aluminum Conductors

Low Smoke Zero Halogen Power Cables with Aluminum Conductors

﷼ 37,800-252,000
MOSKABEL LLC 🇷🇺
کابل قدرت AVVG-Png(A)-LS با ولتاژ متناوب نامی تا 1 کیلو ولت شامل

کابل قدرت AVVG-Png(A)-LS با ولتاژ متناوب نامی تا 1 کیلو ولت شامل

﷼ 15,120-50,400
Alyur Cable Plant LLC 🇷🇺
Power Cables with Aluminum Conductors and Paper Insulation, Lead Sheath, 1 kV - ASPG

Power Cables with Aluminum Conductors and Paper Insulation, Lead Sheath, 1 kV - ASPG

﷼ 378,000-1,512,000
MOSKABEL LLC 🇷🇺
Aluminum Conductor Power Cables with Lead Sheath, 1 kV, ASB2лГ

Aluminum Conductor Power Cables with Lead Sheath, 1 kV, ASB2лГ

﷼ 37,800-151,200
MOSKABEL LLC 🇷🇺
کابل قدرت KA9RV.. 6-35kV آلومینیومی با عایق EPR در پوشش PVC

کابل قدرت KA9RV.. 6-35kV آلومینیومی با عایق EPR در پوشش PVC

﷼ 378,000-1,260,000
UGLICHKABEL LLC 🇷🇺
کابل قدرت APvEBPng(A)-HF

کابل قدرت APvEBPng(A)-HF

﷼ 37,800-151,200
KAVKAZKABEL LLC 🇷🇺
کابل قدرت با ولتاژ 0.66; 1kV مدل APvBГ

کابل قدرت با ولتاژ 0.66; 1kV مدل APvBГ

﷼ 37,800-151,200
Samara Cable Company OJSC 🇷🇺
کابل قدرت با هسته آلومینیومی AABVG-10 3x150(عایق)

کابل قدرت با هسته آلومینیومی AABVG-10 3x150(عایق)

﷼ 176,400-630,000
KAMSKY CABLE LLC 🇷🇺
Power Cable with Aluminum Conductors and Paper Insulation for 6-10 kV Applications

Power Cable with Aluminum Conductors and Paper Insulation for 6-10 kV Applications

﷼ 37,800-151,200
KAMSKY CABLE LLC 🇷🇺
کابل قدرت APvPGEng(A)-HF

کابل قدرت APvPGEng(A)-HF

﷼ 37,800-151,200
KAVKAZKABEL LLC 🇷🇺
کابل قدرتی با هسته آلومینیومی AABLSHN6 3x240

کابل قدرتی با هسته آلومینیومی AABLSHN6 3x240

﷼ 378,000-1,260,000
KAMSKY CABLE LLC 🇷🇺
Aluminum Conductor Power Cables with Plastic Insulation APvVGÉ

Aluminum Conductor Power Cables with Plastic Insulation APvVGÉ

﷼ 37,800-151,200
MOSKABEL LLC 🇷🇺
Power Cables with Aluminum Conductors and Paper Insulation, Lead Sheathed

Power Cables with Aluminum Conductors and Paper Insulation, Lead Sheathed

﷼ 378,000-1,512,000
MOSKABEL LLC 🇷🇺
کابل قدرت با ولتاژ تا 1kV APvVG

کابل قدرت با ولتاژ تا 1kV APvVG

﷼ 37,800-252,000
EVKABEL LLC 🇷🇺
کابل قدرت با ولتاژ تا 1kV AVVGng(A)

کابل قدرت با ولتاژ تا 1kV AVVGng(A)

﷼ 25,200-151,200
EVKABEL LLC 🇷🇺
Power Cables with Plastic Insulation for 0.66; 1 kV, Type AVVGng(A)

Power Cables with Plastic Insulation for 0.66; 1 kV, Type AVVGng(A)

﷼ 25,200-151,200
TSVETLIT LLC 🇷🇺
کابل قدرت APvVGng(A)-XL

کابل قدرت APvVGng(A)-XL

﷼ 25,200-151,200
KAVKAZKABEL LLC 🇷🇺

FAQ

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.