Operating temperature
Up to -50 °C to +70 °C
Attenuation factor recalculated for 100 m length and 20 C temperature at 100 MHz frequency
No more than 22.0 dB
Mounting temperature
up to -15°C
Minimum bending radius
6D, where D is the maximum outer size of the cable at not lower than -15°C
Fire hazard class
P1b.8.2.1.2
Near-end transient attenuation for any composition of NEXT pairs at 1/4/10/16/20/31.25/62.5/100 MHz, converted n
at least 65.3/56.3/50.3/47.3/45.8/42.9/38.4/35.3 dB
Wave impedance Zc at frequencies 1-100 MHz
100 [+/-] 15 ohm
RL reflection attenuation at frequencies 1-10/10-20/20/20-100 MHz
25/25/21
Transient attenuation of total influence power at the near end of PS NEXT at fixed frequencies 1/4/10/16/20/31.25/62.5/100 M
at least 62.3/53.3/47.3/44.3/42.8/39.9/35.4/32.3 dB
Electrical resistance of insulation to direct current, recalculated for the length of 1 km and temperature 20 C, not less than
5000 MΩ
Ohmic asymmetry of conductors to direct current between pairs, not more than
4 %
Ohmic asymmetry of conductors to direct current in a working pair, not more than
2 %
Electrical resistance of conductors to direct current, recalculated for the length of 1 km and temperature 20 C, no more than
95 ohm
Nominal core diameter
0.52 mm
Minimum insulation diameter
1.13 mm
Number of conductive cores
4 pcs
Twist type
paired (Nx2xD), where N – number of pairs, D – diameter of conductive core
Sheath material
low-toxicity PVC with reduced fire hazard and low smoke and gas emission
Insulation material
high-density polyethylene
Number of wires in the core
1 pcs
design
shielded, without armor
screen
alumolavsan tape with contact conductor
brand
TechnoLAN F/UTP Cat 5e PVC LS ng(A)-LSLTx