Тауарлар — Кабельдер және сымдар

Flexible Power Cable KGT-P-HL for Outdoor Use

Flexible Power Cable KGT-P-HL for Outdoor Use

₸285-2,850
EM-KABEL LLC 🇷🇺
ППГнг(A)-HF 3х4 күштік кабель

ППГнг(A)-HF 3х4 күштік кабель

₸142.50-855
ENERGETTA LLC 🇷🇺
Low Smoke Zero Halogen Flame Retardant Cables KMPVEng(A)-LS

Low Smoke Zero Halogen Flame Retardant Cables KMPVEng(A)-LS

₸142.50-1,140
Segment Energo LLC 🇷🇺
TSOS2-ng(A)HF Cable for Ground Installation

TSOS2-ng(A)HF Cable for Ground Installation

₸4,275-17,100
INKAB LLC 🇷🇺
Kabel silovoy PvVGN(А)-LS

Kabel silovoy PvVGN(А)-LS

₸427.50-1,710
EM-KABEL LLC 🇷🇺
Flexible Power Cable KGP-P(А)-FRHF 0.66/1 kV

Flexible Power Cable KGP-P(А)-FRHF 0.66/1 kV

₸427.50-1,710
MARPOSADKABEL OJSC 🇷🇺
Кабель КИС-Пнг(А)-HF 1х2х0,78

Кабель КИС-Пнг(А)-HF 1х2х0,78

₸570-1,995
TPD PARITET LLC 🇷🇺
ВВГ-Пнг(А)-LS 3х2,5 күштік кабель

ВВГ-Пнг(А)-LS 3х2,5 күштік кабель

₸199.50-712.50
ENERGETTA LLC 🇷🇺
ПвЭБПнг(А)-HF күштік кабелі

ПвЭБПнг(А)-HF күштік кабелі

₸570-2,850
KAVKAZKABEL LLC 🇷🇺
Optical Fiber Cable TsPS2-ng(A)-HF

Optical Fiber Cable TsPS2-ng(A)-HF

₸42,750-171,000
INKAB LLC 🇷🇺

FAQ

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.