المنتجات — أنظمة التهوية

Thermostatic Control Valve TE5 for Refrigeration Systems

صمام التحكم الحراري TE5 لأنظمة التبريد

SAR 337.50-1,125
ش.ذ.م.م كلاروس 🇷🇺
Thermoregulating Valve with External Pressure Equalization 22ТЕ5-49 АК

صمام تنظيم الحرارة مع توازن الضغط الخارجي 22ТЕ5-49 АК

SAR 337.50-1,125
ش.ذ.م.م كلاروس 🇷🇺
Thermoregulating Valve T1 for Automatic Refrigerant Control

صمام تنظيم الحرارة T1 للتحكم التلقائي في المبرد

SAR 33.75-135
ش.ذ.م.م كلاروس 🇷🇺
Thermoregulating Valve TE2 for Automatic Refrigerant Control

صمام تنظيم الحرارة TE2 للتحكم التلقائي في المبرد

SAR 56.25-315
ش.ذ.م.م كلاروس 🇷🇺
Thermoregulating Valve TE6 for Automatic Refrigerant Control

صمام تنظيم الحرارة TE6 للتحكم التلقائي في المبردات

SAR 337.50-1,125
ش.ذ.م.م كلاروس 🇷🇺

الأسئلة الشائعة

Can air handling units be built to match our project specification?
Yes — AHUs are configured to order. Send the airflow, external pressure, climate data and required sections (heating, cooling, heat recovery, filtration), and the factory returns a technical selection with dimensions, electrical loads and acoustic data. Units arrive as labelled sections for on-site assembly.
Which filter classes are available and are they interchangeable with our current filters?
Filters are produced across standard coarse and fine classes in common frame dimensions, so most replacements are straightforward — match the class and frame size. Custom dimensions are manufactured to order. Many importers set up recurring quarterly shipments, since filters are a consumable with predictable demand.
Are fire dampers accepted by building authorities outside Russia?
Dampers carry certification under EAEU fire safety technical regulations with documented fire-resistance ratings. Acceptance abroad varies: some authorities recognise the test reports directly, others require local certification, for which manufacturers supply complete technical files. Clarify your code requirements before specifying.
What do UV bactericidal recirculators offer for clinics and offices?
Recirculators draw room air past shielded UV lamps and return it, allowing continuous disinfection in occupied rooms. They are extensively used in CIS healthcare. Suppliers state airflow and lamp parameters per model; select capacity by room volume using the manufacturer's tables.
How is a mixed ventilation order shipped most economically?
Grilles, diffusers, valves and filters consolidate into the free space around AHU sections and duct bundles, so a full project usually ships as one or two containers or trucks. For Central Asia, direct trucking takes around 10 to 20 days; sea freight serves the Gulf, Africa and Latin America.