Past kuchlanishli kuch kabellari (1 kV gacha)
O'rta kuchlanishli kuch kabellari (6-35 kV)
O'rnatish va maishiy simlar
Alyuminiy tomirli past kuchlanishli kabellar
Aloqa, signalizatsiya va SKS kabellari
Mis tomirli past kuchlanishli kabellar
Nazorat kabellari
Montaj/o'rnatish kabellari
Kabel muftalari
SIP o'z-o'zini ko'taruvchi simlar
Sim va kabel armaturasi
Kema/neft-gaz/kon kabellari
Kabel aksessuarlari
Optik tolali kabellar
Shnurlar va uzaytirgichlar
Boshqa kabel mahsulotlari
Mis va alyuminiy shinalar
Termoelektrodli kabellar
Montaj simlari
Havo xatlari uchun izolyatsiyasiz simlar
O'rama va emalli simlar
Boshqa
Mahsulotlar — Kabellar va simlar
Kabel nazoratli KPPGEng(A)-FRHF nominal kuchlanishi 0,66 kV
so'm 11,340-45,360
MARPOSADKABEL OJSC 🇷🇺
Mis yoki alyuminiy simli nazorat kabellari, polimer izolyatsiya va qoplama bilan, himoya qoplamalari bilan yoki uysiz, pre
so'm 7,560-75,600
KAMSKY CABLE LLC 🇷🇺
Yong'in tarqatuvchi bo'lmagan nazorat kabellari, polimer kompozitsiyalardan izolyatsiya va qoplama bilan, halogenlar mavjud emas
so'm 11,340-45,360
Samara Cable Company OJSC 🇷🇺
Mis simli va rezina izolyatsiyali nazorat kabeli, nominal o'zgaruvchan kuchlanishi 660 V gacha, chastotasi 100 Gts gacha
so'm 11,340-75,600
KAMSKY CABLE LLC 🇷🇺
Mis simli nazorat kabeli va rezina izolyatsiyasi bilan 660 V gacha bo'lgan o'zgaruvchan kuchlanish uchun
so'm 7,560-75,600
KAMSKY CABLE LLC 🇷🇺
Nazorat kabeli, olovga chidamli, yonish tarqalmaydigan, KPBPng(A)-FRHF markasi, nominal o'zgaruvchan kuchlanish 0,66
so'm 26,460-90,720
SKT GROUP LLC 🇷🇺
Fire-Resistant Control Cable with Copper Conductors - КППГЭнг(А)-FRHF
so'm 11,340-45,360
CONCORD LLC 🇷🇺
Low Smoke Non-Flame Spread Control Cables (Up to 37 Conductors)
so'm 7,560-75,600
Irkutskkabel OJSC 🇷🇺
Nazorat kabellari yong'in tarqatmaydigan AKVBBshvng(A)
so'm 15,120-75,600
Samara Cable Company OJSC 🇷🇺
Fire-resistant power and control cable with polymer insulation and sheath
so'm 11,340-45,360
EKZ OJSC 🇷🇺
Nazorat kabellari, olovga chidamli, yonishni tarqatmaydigan, past tutun va gaz chiqaradigan, bronlangan KVBbShvng(A)-FRLS
so'm 18,900-75,600
Samara Cable Company OJSC 🇷🇺
Power Cables with Aluminum Conductors and Paper Insulation, Lead Sheathed, Including Control Cores
so'm 113,400-453,600
MOSKABEL LLC 🇷🇺
Control Cables with Copper or Aluminum Conductors, PVC Insulation and Sheath
so'm 3,780-45,360
AGRO CABLE LLC 🇷🇺
Sovuq iqlim hududlari uchun nazorat kabellari KVVGng(А)-XЛ
so'm 11,340-45,360
Samara Cable Company OJSC 🇷🇺
Yong'in tarqatuvchi nazorat kabellari, polimer kompozitsiyalaridan izolyatsiya va qoplama bilan, halogenlar mavjud emas KPBPng
so'm 11,340-45,360
Samara Cable Company OJSC 🇷🇺
Umumiy kabel nazorat-o'lchov asboblari va uskunalari uchun SKAB 250Kng(A)-FRHF-XL
so'm 22,680-90,720
SPECKABEL LLC 🇷🇺
Nazorat kabellari, yonmaydigan, past tutun va gaz chiqarish bilan, mis simlar bilan, etilen propilen izolyatsiyasi bilan
so'm 11,340-45,360
MOSKABEL LLC 🇷🇺
Nazorat kabellari, yonish tarqatuvchi emas, olovga chidamli, past tutun va gaz chiqarish bilan, mis simlar bilan, izolyatsiya bilan
so'm 11,340-45,360
MOSKABEL LLC 🇷🇺
Nazorat kabellari, yonmaydigan, past tutun va gaz chiqarish bilan, mis tolalari bilan, etilen propilen izolyatsiyasi bilan
so'm 11,340-45,360
MOSKABEL LLC 🇷🇺
FAQ
•How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
•What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
•Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
•What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
•How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
•Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.