Mahsulotlar — Kabellar va simlar

Heat Shrink Tubing TTPP - Reliable Cable Insulation

Heat Shrink Tubing TTPP - Reliable Cable Insulation

so'm 3,780-45,360
MEMOTHERM-MM OJSC 🇷🇺
MyFTA STпУткп(нгLS)-10-3х(120-240)OП Cable Joint Connector

MyFTA STпУткп(нгLS)-10-3х(120-240)OП Cable Joint Connector

so'm 189,000-756,000
RIKA GROUP LLC 🇷🇺
Кабель муфты 1ПКНТ-35 35 кВ

Кабель муфты 1ПКНТ-35 35 кВ

so'm 113,400-756,000
MZEI OJSC 🇷🇺
Kabel muftalari 3STp-10 MKS

Kabel muftalari 3STp-10 MKS

so'm 113,400-453,600
MZEI OJSC 🇷🇺
MyFTA Heat-Shrinkable Connecting Sleeve STpU-10 -3x (10...240)

MyFTA Heat-Shrinkable Connecting Sleeve STpU-10 -3x (10...240)

so'm 113,400-453,600
RIKA GROUP LLC 🇷🇺
MPP muftasi

MPP muftasi

so'm 11,340-45,360
SSD OJSC 🇷🇺
Muftalar 3PKVTpb-20 20 kV

Muftalar 3PKVTpb-20 20 kV

so'm 113,400-453,600
MZEI OJSC 🇷🇺
End Plug Connector for 4ПКВ(Н)Тпб-1-35/50(Б) Cables

End Plug Connector for 4ПКВ(Н)Тпб-1-35/50(Б) Cables

so'm 3,780-30,240
GARDIFLOW LLC 🇷🇺
End Cable Joint MyFTA PKVNTpN-1-5x(25-50) for Plastic Insulated Cables

End Cable Joint MyFTA PKVNTpN-1-5x(25-50) for Plastic Insulated Cables

so'm 37,800-226,800
RIKA GROUP LLC 🇷🇺
Kabellar uchun muftalar 3PSTb-20 (35-50, 70-120, 150-240)

Kabellar uchun muftalar 3PSTb-20 (35-50, 70-120, 150-240)

so'm 113,400-529,200
MZEI OJSC 🇷🇺
Kabellar uchun muftalar 1PKVNT-1 (10-800)

Kabellar uchun muftalar 1PKVNT-1 (10-800)

so'm 11,340-75,600
MZEI OJSC 🇷🇺
MyFTA STgt-1-1(500) Connecting Joint for Single-Core Cables

MyFTA STgt-1-1(500) Connecting Joint for Single-Core Cables

so'm 189,000-604,800
RIKA GROUP LLC 🇷🇺
End and Connecting Insulated Cable Couplings KV(N)tp10

End and Connecting Insulated Cable Couplings KV(N)tp10

so'm 529,200-2,268,000
MEMOTHERM-MM OJSC 🇷🇺
Heat-Shrink Gloves TUPng-HF for Cable Insulation

Heat-Shrink Gloves TUPng-HF for Cable Insulation

so'm 18,900-226,800
MEMOTHERM-MM OJSC 🇷🇺
Mufta koncevaya 5PKV(N)Tpб-1-35/50(B)

Mufta koncevaya 5PKV(N)Tpб-1-35/50(B)

so'm 11,340-45,360
GARDIFLOW LLC 🇷🇺
Pass-Through Joint MOG-U for Urban Cables

Pass-Through Joint MOG-U for Urban Cables

so'm 1,134,000-3,780,000
SSD OJSC 🇷🇺
TTEx Heat-Shrink Tubes for Electrical Insulation

TTEx Heat-Shrink Tubes for Electrical Insulation

so'm 3,780-45,360
MEMOTHERM-MM OJSC 🇷🇺
MGR muftasi

MGR muftasi

so'm 113,400-453,600
SSD OJSC 🇷🇺
STp1 Connectors for Power Cables

STp1 Connectors for Power Cables

so'm 1,134,000-4,536,000
MEMOTHERM-MM OJSC 🇷🇺
4-Pole Branching Connector for 4-Core Cables 4ПТО-1-50/95-4-35

4-Pole Branching Connector for 4-Core Cables 4ПТО-1-50/95-4-35

so'm 113,400-453,600
GARDIFLOW LLC 🇷🇺
Classic Through Cable Coupling MOH-C for Urban Cables

Classic Through Cable Coupling MOH-C for Urban Cables

so'm 1,134,000-3,780,000
SSD OJSC 🇷🇺
Heat Shrink Tubes TTE-C - Electrical Insulation Protection

Heat Shrink Tubes TTE-C - Electrical Insulation Protection

so'm 3,780-45,360
MEMOTHERM-MM OJSC 🇷🇺
Muftalar kabel 4PST-1 (25-50, 70-120, 150-240) MKS

Muftalar kabel 4PST-1 (25-50, 70-120, 150-240) MKS

so'm 37,800-226,800
MZEI OJSC 🇷🇺
Heat Shrink Cable Terminations 3, 4, 5PKNTp-1 (10-240mm²)

Heat Shrink Cable Terminations 3, 4, 5PKNTp-1 (10-240mm²)

so'm 11,340-75,600
MZEI OJSC 🇷🇺
Muftalar kabel 1PST-10 (25-50, 70-120, 150-240) MKS

Muftalar kabel 1PST-10 (25-50, 70-120, 150-240) MKS

so'm 37,800-226,800
MZEI OJSC 🇷🇺
Hydrophobic Cable Joint Kit MGP for TP Cables

Hydrophobic Cable Joint Kit MGP for TP Cables

so'm 113,400-378,000
SSD OJSC 🇷🇺
MyFTA PSTpb-10-1x(150-240)-bg Cable Joint Connector

MyFTA PSTpb-10-1x(150-240)-bg Cable Joint Connector

so'm 113,400-453,600
RIKA GROUP LLC 🇷🇺

FAQ

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.